The MC1 receiver has a built in fuse that provides protection from electrical shorts and overload.
Avoid static discharge, especially to the screw terminals and the eye jack.
Connections to the receiver are indicated in the drawing below and all connection wires must conform to the motor
manufacture’s recommendation and prevailing electrical codes. The switch and control system wires should be at least 24
AWG and no larger than 18 AWG. The AC power connection wires must be no larger than 12AWG solid or stranded, one
wire per terminal.
RS232 Data from Control System
RS232 Data to Control System
Signal Ground & Manual Switch Common
Manual Down Switch
Manual Up Switch
Ground
Neutral
Motor
Motor
AC IN:
Motor:
Ground
Hot
Neutral
Program LED
EYE jack
FUSE
115VAC version:
Rated at 3.8 Amps, 1/8th HP, fuse should be 4 Amp 250V 5x20mm fast or slow blow.
230VAC version:
Rated at 1.9 Amps, 1/8th HP, fuse should be 2 Amp 250V 5x20mm fast or slow blow.
5 Volt power from the eye jack is limited to one eye.
No other accessories may be powered by this unit. Other accessories
may be connected to this unit if they are powered by some other means, e.g. an SC1 system or a DCPM.
With a LEFT hand motor connected as shown with the screen coming off the back of the roller and the control in its default
setting:
Open commands on the Bus will cause the screen to retract into the headrail.
This agrees with the top button on the Salara transmitter (printed arrow pointing “up”) sending Open 1 command.
Up commands on the serial link will cause the screen to retract into the headrail.
Shorting the Manual Up lead to the common lead will cause the screen to retract into the headrail.
Open commands on the Bus will cause the MC1 to apply power to the RED terminal block (the one on the end).
Przeglądanie stron 0
1 2 3 4 5 6 7 8 9

Podsumowanie treści

Strona 1 - page 1 / 9

MC1 V3 Installation & Programming page 1 / 9 The MC1 receiver has a built in fuse that provides protection from electrical shorts and over

Strona 2 - page 2 / 9

MC1 V3 Installation & Programming page 2 / 9 This Sheet uses # for the receiver's main channel number - new units will use a 1 where

Strona 3 - page 3 / 9

MC1 V3 Installation & Programming page 3 / 9 Desired Change LED: on blink blink off Turn off all “A” intermediate stops (factory d

Strona 4 - page 4 / 9

MC1 V3 Installation & Programming page 4 / 9 2 “Fast” automatically enables Momentary Motor Action 3 Override switch is SPST so that mode

Strona 5 - page 5 / 9

MC1 V3 Installation & Programming page 5 / 9 RS232 Serial Command Protocol Link must be set to 9600 baud 8N1 (8 data bits, no parity, 1 st

Strona 6 - page 6 / 9

MC1 V3 Installation & Programming page 6 / 9 Buffer 7 overflowed and all data was purged O followed by X-on Buffer 7 is half full X-off

Strona 7 - page 7 / 9

MC1 V3 Installation & Programming page 7 / 9 If 2 way serial is not used, then several MC1 receivers can all be on one RS232 link. The pr

Strona 8 - page 8 / 9

MC1 V3 Installation & Programming page 8 / 9 A minimum threshold of 0 is special. The minimum load sense is not checked. This is useful i

Strona 9 - page 9 / 9

MC1 V3 Installation & Programming page 9 / 9 Appendix: Special characters Character Description ASCII Character Number “ ; ” Semicolon